Description
Product Overview
The ADC 4000p airway is engineered for dependable performance in critical airway management situations. Constructed from high‑quality medical‑grade polyethylene, the tube offers a smooth, low‑friction surface that minimizes trauma to delicate airway tissues while providing sufficient rigidity for easy insertion. A reinforced bite block, integrated directly into the tube wall, prevents patient‑induced occlusion and protects the device from being bitten through, extending the functional lifespan of each unit even in the most demanding environments.
Each airway is single‑use and non‑sterile, designed for rapid deployment in emergency departments, operating rooms, intensive care units, and pre‑hospital settings. The product dimensions are compact—7.8 x 5.3 x 1.9 inches—and the weight is a lightweight 1.92 ounces, ensuring ease of handling and storage. The model number 4000p reflects the series designation within ADC’s airway portfolio, and the product has been available since March 5, 2008, earning a solid reputation reflected in a 4.7‑star rating from over 600 verified customer reviews.
Six sizes are offered, ranging from 40 mm to 110 mm in internal diameter. Each size is embossed directly on the tube and color‑coded for instant visual identification, reducing the risk of size mismatch during high‑stress scenarios. The color‑coding follows a logical progression from light to dark hues, facilitating quick selection by clinicians who may be wearing gloves or operating under limited lighting conditions.
![[Product front view showing all components]](https://www.eventlife.store/wp-content/uploads/2026/06/fec50ab5fcee449f99562cb2abf0b254.jpg)
Usage
Designed for versatility, the ADC 4000p airway excels in a variety of clinical and field applications. In hospital emergency departments, it serves as a reliable primary airway adjunct for patients who cannot maintain a patent airway due to trauma, sedation, or neurological compromise. Its smooth polyethylene construction allows for swift insertion with minimal resistance, while the reinforced bite block ensures that the airway remains open even if the patient attempts to bite down.
In pre‑hospital environments, such as ambulance services and air medical transport, the lightweight and compact design enables rapid packing and deployment. The color‑coded sizing system is especially valuable for paramedics who must make swift decisions without the benefit of extensive equipment inventories. The airway’s single‑use nature eliminates the need for re‑processing, saving valuable time and reducing the risk of cross‑contamination.
Operating rooms benefit from the device’s predictable performance during anesthesia induction and emergence phases. Anesthesiologists appreciate the tube’s compatibility with standard airway adjunct accessories, including connectors and securing straps. The reinforced bite block provides an added layer of safety during patient emergence, when involuntary biting is more common.
Intensive care units frequently employ the ADC 4000p airway for patients requiring prolonged ventilation support. While the device is intended for single‑use, its durability ensures that it can withstand the rigors of extended use without compromising structural integrity. The non‑sterile status is appropriate for settings where aseptic technique is maintained through standard infection control protocols.
Why Choose Us
ADC has a long history of delivering high‑quality medical devices that meet stringent regulatory standards. The 4000p airway reflects the company’s commitment to innovation, safety, and user‑centered design. Each unit undergoes rigorous quality assurance testing, including material purity analysis, dimensional verification, and functional performance assessments, ensuring that clinicians receive a product they can trust.
Our manufacturing process incorporates advanced extrusion technology that yields a uniform polyethylene wall thickness, reducing the likelihood of weak points that could lead to failure. The reinforced bite block is molded as an integral part of the tube, eliminating the need for separate components that could detach or shift during use.
Customer support is a cornerstone of ADC’s service model. Purchasers gain access to a dedicated technical assistance team available 24/7 to answer product‑related questions, provide guidance on proper usage, and facilitate rapid resolution of any concerns. Additionally, ADC offers comprehensive documentation, including detailed sizing charts, insertion techniques, and maintenance guidelines, all accessible through our online portal.
Environmental responsibility is also a priority. While the airway is single‑use, the polyethylene material is recyclable where local regulations permit, and the packaging is designed to minimize waste. ADC continuously evaluates its supply chain to reduce carbon footprint and promote sustainable manufacturing practices.
Key Features
- Smooth polyethylene construction reduces tissue irritation and eases insertion.
- Integrated reinforced bite block prevents occlusion and protects against patient biting.
- Six color‑coded sizes (40 mm‑110 mm) enable rapid identification and selection.
- Lightweight, compact design simplifies storage and transport for emergency teams.
- 24/7 technical support and detailed user documentation ensure confidence and assistance.
FAQ
Is the ADC 4000p airway sterile?
No, the airway is supplied as a non‑sterile, single‑use device. It is intended for use in environments where standard aseptic techniques are applied.
Can the airway be reused after cleaning?
Because the product is designated for single‑use only, reprocessing is not recommended. Reuse could compromise the integrity of the reinforced bite block and increase infection risk.
What sizes are available and how are they identified?
The airway is offered in six internal diameters: 40 mm, 55 mm, 70 mm, 85 mm, 100 mm, and 110 mm. Each size is embossed on the tube and color‑coded, allowing clinicians to quickly match the appropriate size to the patient.
Is the airway compatible with standard connectors?
Yes, the ADC 4000p airway features a universal connector that fits most standard ventilation circuits and adjunct equipment used in hospitals and pre‑hospital settings.
What is the typical shelf life of the product?
The airway has a shelf life of five years from the date of manufacture when stored in a cool, dry environment away from direct sunlight. The packaging includes the expiration date for reference.




Zoll AED Soft Case Black Replacement for ZOLL AED Plus 9.25×8.25×6.25
Reviews
There are no reviews yet.